FA-TB8XY3 | MITSUBISHI Conversion module FA-TB8XY3
MITSUBISHI FA-TB8XY3 Manual And Instructions
FA-TB8XY3 datasheetPDF datasheet

MITSUBISHI FA-TB8XY3 Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB8XY3
Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module.

Convert connector to screw relay terminal.
The action of the signal of the conversion module is shown in the light of the lamp.
Positive common end display. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points MITSUBISHI FA-TB8XY3.
Remote register: 1024 words.
RAS function.
End cap FA-TB8XY3
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space MITSUBISHI FA-TB8XY3.
Management of abnormal information through the RAS function
An error occurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network.
Even if the power of the system is cut off, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime MITSUBISHI FA-TB8XY3. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormall detection function of the input signal which is outside the range of the set range FA-TB8XY3.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter rannge extension
Range of scalable input range FA-TB8XY3.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected.