AJ65SBTB1-16DT2 | MITSUBISHI DC input / transistor output module AJ65SBTB1-16DT2
MITSUBISHI AJ65SBTB1-16DT2 Manual And Instructions
AJ65SBTB1-16DT2 datasheetPDF datasheet

MITSUBISHI AJ65SBTB1-16DT2 Product information and technical parameters:
Brand: MITSUBISHI
Name: DC input / transistor output module
Model: AJ65SBTB1-16DT2
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
External connection: 1 line /1 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool.

Output type: relay output.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A.
External connection: 1 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole MITSUBISHI AJ65SBTB1-16DT2.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition AJ65SBTB1-16DT2
Can be installed along the 6 direction. Input type: DC input, positive public end / negative public end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 1 wire MITSUBISHI AJ65SBTB1-16DT2.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. A pack of 20.
Applicable models:
AJ65SBTC - - - type remote I/O module MITSUBISHI AJ65SBTB1-16DT2.
AJ65VBTCU - - - type remote I/O module.
AJ65VBTCU- - type remote I/O module. Fast connector type.
Voltage input.
Number of channels: 8 channels.
Occupied the number of stations: Ver.1 mode occupied 3 stations, Ver.2 mode occupied 1 stations.
Station type: remote equipment station.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the oon-line unification to adjust AJ65SBTB1-16DT2.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on stepp by step AJ65SBTB1-16DT2.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.


...More relevant models >>>>