AJ65BTB2-16D | MITSUBISHI DC input module AJ65BTB2-16D
MITSUBISHI AJ65BTB2-16D Manual And Instructions
AJ65BTB2-16D datasheetPDF datasheet

MITSUBISHI AJ65BTB2-16D Product information and technical parameters:
Brand: MITSUBISHI
Name: DC input module
Model: AJ65BTB2-16D
Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 2 wire.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.

Points: 32 points
.
Rated voltage: DC24V.
Connection type: connector
.
Three remote components can be connected to the CC-LINK system.
Remote I/O: refers to those who require only the ON/OFF control function of the field components, such as digital I/O or pneumatic valve, etc..
In this type of communication can only be carried out in the bit data MITSUBISHI AJ65BTB2-16D.
Remote components: refers to those that require processing of the register data of the field components, such as analog I/O and counters, etc AJ65BTB2-16D.
In this type of component, in addition to the bit data can be carried out in the register data communication.
Intelligent remote: this type of component is to allow the main station or other stations to access the action, to collect data and control the local PLC station,
GOTS and programmer interface unit are of this type MITSUBISHI AJ65BTB2-16D. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No MITSUBISHI AJ65BTB2-16D.
Rated load voltage / current: DC24V/0.5A.
External connection: 3 line /2 line type.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. Output type: transistor outpuut, source AJ65BTB2-16D.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CONN type AJ65BTB2-16D.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.