Using A6SIM-X64Y64 simulation I/O module in the system before the connection can be carried out to control the process of debugging.
The simulation unit consists of 16 blocks of 4 switches and 4 LED LEDs.
Liquid crystal display: 16 characters x 2 lines,
For data access (the state of operation of the central processor, device monitor / change). Axis of control: 2.
A1SD71-S2 is a linear interpolation of the pulse sequence output type positioning control module,
The stepper motor is suitable for the servo motor MITSUBISHI A6SIM-X64Y64.
The fastest positioning speed up to 200Kpps, positioning range 1-16252928 pulse
A6SIM-X64Y64
According to the specific application setting positioning unit,
If the number of pulses, mm, inches or degrees, but also to provide compensation to improve the positioning accuracy. Cable length: 3 meters
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable MITSUBISHI A6SIM-X64Y64. Cable length: 0.33 meters.
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable MITSUBISHI A6SIM-X64Y64. Reader writer 2 channel connection, AnSCPU/QnASCPU.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (oor address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next rround of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work A6SIM-X64Y64 A6SIM-X64Y64.