A1SY18AEU | MITSUBISHI Relay output module A1SY18AEU
MITSUBISHI A1SY18AEU Manual And Instructions
A1SY18AEU datasheetPDF datasheet
A1SY18AEU User's Manual

MITSUBISHI A1SY18AEU Product information and technical parameters:
Brand: MITSUBISHI
Name: Relay output module
Model: A1SY18AEU
Output type: relay.
Output points: 8 points.
Load voltage: AC240/DC24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 1.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language. In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system.
Mainly used for other programming languages more difficult to achieve the user program.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Need to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers. Poor visibility and operability.

A1ST60 analog timer module has 8 analog timers.
Each timer can be set between 0.1-600S,
Its accuracy plus or minus 2%.
Dial setting on the timing constant panel of the timer,
With a small screwdriver can be easily adjusted. SRAM memory card.
RAM capacity: 256KB. AnS, QnAS bus connection, the reader to write program 1 channel connection MITSUBISHI A1SY18AEU. Number of channels: 2 channels.
Sensing method and temperature range: PT100 A1SY18AEU
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperature measurement input and built-in PID algorithm control output, can be used in a variety of temperature control occasions.
Each component controls up to 4 loops at most MITSUBISHI A1SY18AEU.
Thermocouple input or PT100 3 wire temperature sensor input.
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function. Axis of control: 3 axis linkage, 3 axis independence.
Interpolation function: 3 axis linear interpolation, 3 axis arc interpolation.
A1SD75 series components show the MITSUBISHI in the manufacture and design of CNC, frequency converter,
Integrated technical experience in servo system and PLC MITSUBISHI A1SY18AEU.
These components have a wealth of features that are sufficient to meet the highest requirements in the application of positioning control.
A1SD75M, SCC net compatible controller, SSC network is the MITSUBISHI servo system control network.
In this network, the MR-H-13, MR-J-B, and MR-J2 servo amplifiers can be connected to a controller via a network system,
The connection is replaced by a pulse sequence and a voltage signal. I/O slots: 8 slots.
Could you install the power module.
Outline dimension: 420*130.
There are two types of extended floor,
A power module can be inserted, and the other one is not.

The choice of any type of substrate depends on the total DC5V current consumption and the power supply on the CPU main substrate A1SY18AEU.
If the total demand is less than the power output, no additional power supply,
Then you can choose a more ecconomical expansion board A1SY18AEU.
Both ends of the main base plate of the CPU have an expansion interface, and can be used for extending the cable connection.