A1SJ71QE71N-T | MITSUBISHI Network module A1SJ71QE71N-T
MITSUBISHI A1SJ71QE71N-T Manual And Instructions
A1SJ71QE71N-T datasheetPDF datasheet
A1SJ71QE71N-T User's Manual

MITSUBISHI A1SJ71QE71N-T Product information and technical parameters:
Brand: MITSUBISHI
Name: Network module
Model: A1SJ71QE71N-T
10BASE-T.

CC-Link master / slave station.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work MITSUBISHI A1SJ71QE71N-T MITSUBISHI A1SJ71QE71N-T A1SJ71QE71N-T
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work MITSUBISHI A1SJ71QE71N-T. Program memory capacity: 8k.
Input / output points: maximum 256 points.
A scan cycle of PLC must pass through three stages: input sampling, program execution and output refresh.
PLC in the input sampling phase: first of all, in order to scan the sequence of all existing input latches in the input terminal of the state or input data read,
And write it into the corresponding input status register,
Refresh the input, then close the input port, enter the program execution stage. Number of channels: 4 channels.
Sensing method and temperature range: PT100.
A1S64TC series component is a kind of temperature controller combined with ANS sseries CPU A1SJ71QE71N-T.
Components with temperature measurement input and built-in PID algorithm control output, can be used in a variety of temperature control occasions.
Each component controls up to 4 loops at most.
Thermocouple input or PT100 3 wire temperature sensor input A1SJ71QE71N-T.
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function.