Safety grade (SIL): SIL 3 (IEC 61508).
Performance level (PL): e PL (13849-1 EN/ISO).
Operation control mode: stored procedures repeated operation.
Program capacity: 1200K (security program: 40K).
Program memory: 4800K.
Soft element / tag memory: 3370K.
Data memory: 40M.
Unified program development environment.
Whether the general control procedures or safety control procedures, can be integrated into 1 Engineering documents,
Unified management by Works3 GX
QD74MH8 The troublesome operation can save more than one project file management.
When you create a security control program, you are also the same as when you create a general control program,
Various features of GXWorks3 can be developed using the support program.
Improve production efficiency through high responsiveness and rich program capacity.
Efficient use of high performance iQ-R CC-Link series and IE Field MELSEC networks,
Improve responsiveness and improve production efficiency.
In addition, the security control program capacity increased to 40K, about 3 times in the past.
Safe CPU can be used to deal with complex large capacity programs. Function: high performance and low price in the middle end model.
Picture size: 8.4 inches.
Resolution: VGA.
Display: TFT color.
Panel color: black.
Power type: DC24V.
The highest level model with multi touch and gesture features.
Specification rich, design at ease.
GT27 standard supports SD memory card and standard equipped with Ethernet, RS-232, RS-422/485, host/device USB interface.
Even in the log, script, alarm, soft component data transmission, such as high load processing period, but also to achieve smooth operation of the screen.
In addition, also supports video, animation playback, video input and RGB input and output, can use all the features of GOT2000.
Can be programmed CPU and other procedures, parameters, such as data storage (backup) to the SD GOT memory card, USB memory.
When the programmable controller fails, batch write back (recovery) program.
1, the human body sensor
People will be able to automatically detect and display the picture.
2, USB interface: device USB (Mini-B USB)
Can connect to the computer to transfer data.
3, USB interface: host USB (USB-A)
GOT data can be transmitted through the USB memory or read log data and other data,
Can also be connected to the USB mouse, keyboard use.
4, the extension of the interface
Communication module and optional module can be installed.
5, Ethernet interface
Up to 4 different manufacturers can be connected to the FA machine.
6, RS-232 interface
Can connect all kinds of FA machine, bar code reader, serial printer.
7, RS-422/485 interface
Can be connected to a variety of FA machines, bar code reader.
8, SD memory card slot
Can save alarm and log data, such as a large number of data.
QD74MH8 Operation manual/Instructions/Model selection sample download link: