Type: 18 point terminal.
Input: DC - 10 ~ 10V, DC0 ~ 20mA.
Conversion speed: 400 s (1ms/ch).
Number of channels: 4 channels.
The conversion speed of the analog input module can be selected from 100 mu s/ channel, 400 mu s/ channel and 1 mu s/ channel.
The conversion speed of the analog output module is 100 mu s/ channel.
By combining the analog input module and the expansion module, the switching time can be controlled more precisely
HC-SFE202 (trigger conversion function)
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 30kw.
SLD converter rated current: 62.0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. Analog channel: 8 channels.
Input / output (resolution): 0 ~ 4000.
Conversion speed: 100ms/8 channel.
Analog module installation.
Power supply: AC170V ~ 264V.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
HC-SFE202 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HC-SFE202&select=5