Motor series: ultra low inertia, low power.
Rated output power: 0.1kw.
Rated speed: 3000r/min.
Whether to bring the brakes: with.
Axis end: D type shaft.
Protection level: IP55 does not include the shaft part and the connector.
Features: ultra low inertia is suitable for high frequency operation.
Application examples: the insertion device, the assembly machine. Input voltage range: DC110V.
Output voltage: DC5V
GT2710-VTWA
Output current: 8A.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate. Max input / output points: 24 points.
Supply voltage: 100 - 240VAC.
Input points: 14 points.
Output points: 10 points.
Output type: transistor.
Power consumption (W): 32.
Weight (kg):0.5.
Size (WxHxD) mm:90x90x75.
Rich functionality.
FX series of products are rich in variety, users can be based on cost or application,
Choose the most suitable product. Will find a suitable model for the user site.
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc..
CPU, power supply, input and output integration.
Display module or function expansion board can be less installed.
In addition, you can also reduce the input output or special module.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 90kw.
SLD converter rated current: 475A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display.
GT2710-VTWA Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=GT2710-VTWA&select=5