LK Automation Limited LK Automation Limited
Brand Sort: MITSUBISHI
Home >> Price
GT1030-LWD-C Market price | GT1030-LWD-C Introduction
MITSUBISHI GT1030-LWD-C
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 line /2 line type.
Type of input and output terminal GT1030-LWD-C
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Input points: 16 points.
Input voltage and current: 120V ~ 6mA AC100.
Input response time: 30ms.
16 point /1 a public side.
Output points: 16 points.
Output voltage: AC100 ~ 120V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: silicon controlled output.
8 point /1 a public side.
50 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
GT1030-LWD-C Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=GT1030-LWD-C&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
4.5 Inch Touch Screen
GT1030-LWD2
MITSUBISHI 4.5 Inch Touch Screen GT1030-LWD2
Series introduction: set a numer of as
MITSUBISHI
4.5 Inch Touch Screen
GT1030-LWDW2
MITSUBISHI 4.5 Inch Touch Screen GT1030-LWDW2
Series introduction: set a numer of as
MITSUBISHI
4.5 Inch Touch Screen
GT1030-LWLW
MITSUBISHI 4.5 Inch Touch Screen GT1030-LWLW
Series introduction: set a numer of as
MITSUBISHI
4.5 Inch Touch Screen
GT1030-LBD2
MITSUBISHI 4.5 Inch Touch Screen GT1030-LBD2
Series introduction: set a numer of as