The length of the line: 20M.
Relay type.
IP level: IP20.
Bending life: standard.
Encoder with cable (amplifier side); for HF-KP/HF-MP series. Program memory capacity 14K.
Input and output points to the maximum 512 points.
A scan cycle of PLC must pass through three stages: input sampling, program execution and output refresh.
PLC in the input sampling phase: first of all, in order to scan the sequence of all existing input latches in the input terminal of the state or input data read,
And write it into the corresponding input status register,
Refresh the input, then close the input port, enter the program execution stage
FX9GT-CAB0 Master station module.
DC5V consumption current: 150mA.
Data communication with various machines using Ethernet.
FX3 series through Ethernet expansion device,
The monitoring and maintenance of equipment can be easily carried out in a place far from the scene.
Various machine communication with MODBUS protocol
Special adapter for MODBUS communications,
FX3 series can be used as a master or slave station with a variety of MODBUS protocol machine communication.
High speed counter equipped with 6 to 8 channels.
FX series of all models are standard with a high-speed counter.
Through a simple procedure to achieve high speed control.
Through the CC-Link and a variety of machine communications, the province of wiring.
Using CC-Link to control a variety of FA machines.
FX3G (*) /FX3U (C) series can be expanded by CC-Link control points. Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Automatically transfer the record file to the FTP server,
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording.
FX9GT-CAB0 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX9GT-CAB0&select=5