LK Automation Limited LK Automation Limited
Brand Sort: MITSUBISHI
Home >> Price
FX3U-48MT/ES-A Market price | FX3U-48MT/ES-A Introduction
MITSUBISHI FX3U-48MT/ES-A
Uses: MR-BAT6V1SET-A, MR-BT6VCASE use.Output points: 24 points.
Voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
36 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor FX3U-48MT/ES-A
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. E81WH4W, QE83WH4W special transformer.
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.
FX3U-48MT/ES-A Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FX3U-48MT/ES-A&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
PLC
FX3U-48MR/ES-A
MITSUBISHI PLC FX3U-48MR/ES-A
Max input / output points: 48 points. Su
MITSUBISHI
PLC
FX3G-40MT/ES-A
MITSUBISHI PLC FX3G-40MT/ES-A
Input points: 24 points. Output points:
MITSUBISHI
PLC
FX3U-48MR/DS
MITSUBISHI PLC FX3U-48MR/DS
Max input / output points: 48 points. Po
MITSUBISHI
PLC
FX3U-48MT/DS
MITSUBISHI PLC FX3U-48MT/DS
Max input / output points: 48 points. Po