Motor series: medium inertia, medium capacity.
Using a serial absolute / incremental encoder.
Rated output power: 3.5kw.
Rated speed: 3000rpm.
With the brake: without.
Shaft end: straight shaft.
When the AC servo motor has no control voltage, only the pulsating magnetic field generated by the excitation winding is generated in the stator, and the rotor is still not moving.
When the control voltage is controlled, a rotating magnetic field is generated in the stator, and the rotor rotates in the direction of the rotating magnetic field,
In the case of constant load, the speed of the motor varies with the size of the control voltage,
When the phase of the control voltage is reversed, the servo motor will reverse
FX3S-20MT/DSOutput points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
16 points / a common end.
38 point terminal station.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
FX3S-20MT/DS Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX3S-20MT/DS&select=5