MITSUBISHI FX2N-32MT-001
5 slots.
Can be installed in the power supply unit for A series units installed QnA/.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage FX2N-32MT-001
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate. Type: 40 pin (FCN) connector.
Input / output form: differential input /DC input, uniform output: transistor output (drain type).
Number of channels: 2 channels.
Maximum 8Mpps count can be carried out. Using PWM output function, can achieve 0.1 s units of the very fine output control.
With the measurement resolution of 100ns, the measurement of the pulse width can be used to measure the pulse width.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station.
FX2N-32MT-001 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FX2N-32MT-001&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
PLC
FX1S-10MT-001
MITSUBISHI PLC FX1S-10MT-001
Total points: 10 points. Input points: 6
MITSUBISHI
PLC
FX2N-32MT-D
MITSUBISHI PLC FX2N-32MT-D
Max input / output points: 32 points. Po
MITSUBISHI
PLC
FX2N-32MR-ES/UL
MITSUBISHI PLC FX2N-32MR-ES/UL
Max input / output points: 32 points. Su
MITSUBISHI
PLC
FX1N-40MT-001
MITSUBISHI PLC FX1N-40MT-001
Total points: 40 points. Input points: 2