Type of input: DC leakage.
Input points: 32 points.
Input voltage: DC12/24.
Input current: 3/7mA.
Output type: transistor drain type.
Output points: 32 points.
Common public end points: 32.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control
FX-48ET
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal.
So the standard telecommunication number, the conversion between the number of operations to use a variety of computing.
This requires the resolution of the analog unit and the standard electrical signal. Type: 18 point terminal.
Input / output form: temperature resistance input, transistor output, channel insulation.
Number of stations: 1 stops.
Number of channels: 4 channels.
Sampling period is 250ms/4 channel. Use 1 sets of temperature control module,
Can achieve standard control (heating, cooling) and heating cooling control.
This module has the functions of heating up, maximum current suppression, self diagnosis and so on.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station.
FX-48ET Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX-48ET&select=5