LK Automation Limited LK Automation Limited
Brand Sort: MITSUBISHI
Home >> Price
FR-HEL-H1.5K Market price | FR-HEL-H1.5K Introduction
MITSUBISHI FR-HEL-H1.5K
Output points: 32 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called FR-HEL-H1.5K
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. The adapter with PT100 type temperature sensor (FX3U- - racy -BD)Protective film for 15 inch screen.
Scrub (frame: white), 5.
Applicable model: GT16. 8 slots.
No need to install power.
For QnA/A series.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
FR-HEL-H1.5K Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FR-HEL-H1.5K&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
DC reactor
FR-HEL-H30K
MITSUBISHI DC reactor FR-HEL-H30K
Power: 30kw. Purpose: to suppress the po
MITSUBISHI
DC reactor
FR-HEL-H5.5K
MITSUBISHI DC reactor FR-HEL-H5.5K
Power: 5.5kw. Purpose: to suppress the p
MITSUBISHI
DC reactor
FR-HEL-H7.5K
MITSUBISHI DC reactor FR-HEL-H7.5K
Power: 7.5kw. Purpose: to suppress the p
MITSUBISHI
DC reactor
FR-HEL-H18.5K
MITSUBISHI DC reactor FR-HEL-H18.5K
Power: 18.5kw. Purpose: to suppress the