Use: power cord for basic unit.
Length: 1.0m.
Auxiliary parts for FX3GC and FX3UC. Function extension board for RS-232C communication.
No DC24V consumption, no occupancy of the input output (FX1S and FX1N of the host computer). Servo motor series: low inertia, small capacity.
Rated output: 0.05kw.
Rated speed: 3000r/min.
Electromagnetic brake: No.
Oil seal: incidental (Note 1, note 2, note 3).
Power supply: 200V
FR-A740-355K-CHT
Note 1 through HG-KR and HG-MR series 0.1kW and HG-SR series can be supported.
Note 2 with the speed reducer case, do not configure the oil seal.
Note 3 with oil seal HG-KR, HG-MR series servo motor''s appearance size standard is different.
The rated speed is 3000r/min, the maximum speed is 6000r/min.
The maximum torque of 350% of the rated torque, high torque in the field of high rotation, only to support the HG-KR series products.
Built in absolute position encoder with high resolution.
Standard high resolution absolute position encoder (4194304p/rev (22bit)).
To achieve a higher accuracy of the positioning function.
Improve the environmental performance of HG-KR, HG-MR, HG-RR, HG-UR series of products using IP65. Analog input points: 4 points (thermocouple, PT, constant voltage input).
Output points: transistor output 4 points, 4 point CT input.
Weight: 0.4KG.
Temperature sensor with 4CH input control output,
Double position control, standard PID control,
Heating and cooling PID control, cascade control.
By using the combination of the analog output module,
PID control of voltage or current can be realized.
New with cascade control. Through the master / slave station of the 2 controllers,
According to the temperature change caused by external disturbance, the temperature can be adjusted quickly.
Can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V. Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command): with 1 s coaxial data communication line function.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
FR-A740-355K-CHT Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FR-A740-355K-CHT&select=5