MITSUBISHI AX81-S1
Axis of control: 1.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
7 operating modules required for easy positioning control are provided.
Type of instruction, please refer to the list in front of you.
One can control a shaft.
FX3U, PLC FX2N can connect up to 8 units,
PLC FX2NC can connect up to 4 units,
PLC FX3UC can connect up to 7 units, so that it can control more than one independent axis AX81-S1
Maximum can output 100kHz pulse train.
Positioning control through the control program. Input and output points: 2048 points.
Input / output data points: 8192 points.
Program capacity: 30K.
Basic command processing speed (LD command) s:0.15.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
AX81-S1 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=AX81-S1&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
High speed counting module
AD61-S1
MITSUBISHI High speed counting module AD61-S1
2 channels. 10kpps. Count input signal:
MITSUBISHI
Input module
AX81
MITSUBISHI Input module AX81
Input points: 32 points. Voltage: DC12/2
MITSUBISHI
Interrupt module
AI61-S1
MITSUBISHI Interrupt module AI61-S1
Enter 16 points. Voltage and current: 14