Servo motor series: medium inertia, small capacity.
Rated output: 3.5kw.
Rated speed: 2000r/min.
Electromagnetic brake: incidental.
Oil seal: incidental (Note 1, note 2, note 3).
Power supply: 200V.
Note 1 through HG-KR and HG-MR series 0.1kW and HG-SR series can be supported.
Note 2 with the speed reducer case, do not configure the oil seal.
Note 3 with oil seal HG-KR, HG-MR series servo motor''s appearance size standard is different
AJ55TB32-16DT
Stable driving of medium capacity and medium inertia type products.
Through the optimization of structural design, to achieve the minimum length of the industry.
High speed & high torque. Shorten the positioning time, achieve high-speed equipment.
Reducing the electric torque ripple.
Through the combination of the optimal number of the motor and the slot number, the torque ripple is greatly reduced,
To further realize the smooth constant speed device.
Improve the environmental performance of HG-SR, HG-JR series of products using IP67. Servo motor series: ultra low inertia, small capacity.
Rated output: 0.75kw.
Rated speed: 3000r/min.
Electromagnetic brake: No.
Power supply: 200V.
The rated speed is 3000r/min, the maximum speed is 6000r/min.
The maximum torque of 350% of the rated torque, high torque in the field of high rotation, only to support the HG-KR series products.
Built in absolute position encoder with high resolution.
Standard high resolution absolute position encoder (4194304p/rev (22bit)).
To achieve a higher accuracy of the positioning function.
Improve the environmental performance of HG-KR, HG-MR, HG-RR, HG-UR series of products using IP65. Measurement items: leakage current (Io), resistive leakage current (Ior).
Measuring circuit number: 2 circuits.
Insulation monitoring module for measuring leakage current.
Leakage current can be measured to ensure safety by monitoring the leakage current (Io), can detect the risk of electric shock.
Insulation state measurement of resistive leakage current (Ior) can be monitored continuously and continuously,
In order to continuously monitor the insulation aging status of the equipment.
Each measurement project can be carried out in the 2 phase of the alarm monitoring can be respectively on the leakage current (Io), resistive leakage current (Ior) for the 2 phase of the alarm monitoring,
No ladder diagram program. Alarm monitoring is divided into 2 stages of attention alarm and danger alarm.
A module can measure two circuits of a module can be two circuits on the same line in the same system type power measurement.
In addition, Works2 GX (1.90U version or higher version) can be used to easily set the parameters.
Leakage current (Io), resistive leakage current (Ior).
AJ55TB32-16DT Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=AJ55TB32-16DT&select=5