Total points: 24 points.
Input points: 14 points.
Output points: 10 points.
Voltage: AC220V.
Output type: transistor.
Outline dimension: 90*75*90.
FX1N series is a very powerful micro PLC,
Can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect
AC300R4-25P MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 22.0kw.
Interface type: SSCNET type III fiber communication.
Special specification: suitable for linear servo motor.
Power specification: three phase AC400V.
More advanced real-time automatic tuning by setting response values,
Including the position gain and the gain of speed, all the gain can be adjusted automatically.
32 segment response level can be set.
Advanced vibration suppression control.
An optimal vibration control filter value is automatically set by the automatic tuning function to effectively suppress the vibration of the 100Hz frequency that occurs when the driving part stops.
The automatic tuning function can effectively restrain the vibration of the end of the mechanical arm and reduce the residual vibration in the machine. MELSECNET/MINI (-S3) data link system, A2C system transfer converter.
Plastic fiber cable -GI optical fiber cable.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
AC300R4-25P Operation manual/Instructions/Model selection sample download link: