Signal level: the DC5V, 12V, and 24V differential output can be connected to the DC5V terminal by connecting terminals.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
Can be single phase, dual phase 50kHz hardware counter high-speed input.
High speed uniform output function with hardware comparison circuit.
In the dual phase count, 1, 2, and 4 multiplication modes can be set
A1STA32
Can be licensed and reset by PLC or external input.
Differential output type encoder. Input and output points: 14 points.
Power supply: AC100-240V.
Input points: 8 points.
Output points: 6 points.
Output form: transistor output (drain).
Power consumption: 19W.
Weight: 0.3KG.
Outline dimension: 60x90x75mm.
A new application model.
FX3SA is a basic model on the basis of the basic performance of FX1S above the expansion of the expansion of the new model.
FX3SA is applicable to all kinds of fields of small scale equipment which need to simulate the quantity and function of MODBUS and Ethernet.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and communication function, etc.. Output points: 32 points.
Output form: Transistor (drain type) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.2A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 40 pin connector.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type.
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance.
A1STA32 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A1STA32&select=5