Power: 150kw.
Voltage: 200V.
Sine wave filter.
The voltage and current of the motor can be adjusted to a sine wave.
The sine wave filter is installed to the output terminal of the inverter.
Applicable to FR-A820-03800 (75K) above and FR-A840-02160 (75K) and above frequency converter.
Sine wave filter is equivalent to the operational characteristics of the sine wave power driver, can provide the following benefits
MR-J3-700BS4
Low noise.
No surge current.
Reduce motor loss (standard motor). Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Input points: 32 points.
Input voltage: DC12V/DC24V.
Current: 3/7mA.
Response time: 10ms.
16 points / a common end.
Positive pole sharing.
50 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
MR-J3-700BS4 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J3-700BS4&select=5