Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 130 K step.
Processing speed: 0.0095 s.
Program memory capacity: 520 KB.
Support USB and RS232.
Support installed memory card.
Providing high speed communication between multiple CPU.
High speed and high precision data processing.
The processing speed of the real number (floating point) arithmetic has been greatly improved,
Addition instruction reached 0
GT27-15PSCC014 mu s,
Therefore, it can support the request of high-speed, high-precision processing data processing.
In addition, the new addition of double precision floating point arithmetic instructions,
Simplify the programming, reduces the computational error when executing complex formula.
Shorten the fixed scan interrupt time, high precision device.
The minimum interval of the fixed period interrupt program is reduced to 100 s.
The high speed signal can be accurately obtained, which makes the contribution to the higher precision of the device.Motor series: low inertia, medium power.
Rated output power: 6.0kw.
Rated speed: 1000r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Voltage: 400V type.
Protection level: IP65 (IP67).
Features: low inertia from low speed to high speed, three modes can be selected, suitable for different application range. As a standard port, 30KW or greater power is suitable for flange (type) installation and support foot mounting.
Application example: injection molding machine, semiconductor manufacturing equipment, large conveyor machinery.
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring. Input points: 4 points.
Weight: 0.02kg.
Function expansion board is used in the FX3SA, FX3S, FX3GA, FX3G, FX3GE on the small number of input and output extension of the product,
Can be built into PLC. Type: sensor connector (e-CON).
Input form: DC input, positive pole common end.
Input points: 16 points.
Rated input voltage / current: DC24V (4mA).
External connection: 3 wire.
IE CC-Link field network module type remote unit.
Select input response time from 0ms/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms.
High speed input and output control of single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station.