FR-F840-00250-2-60 Market price | FR-F840-00250-2-60 Introduction
MITSUBISHI FR-F840-00250-2-60
Common cathode input module (standard type).Total points: 20 points.
Input points: 12 points.
Output points: 8 points.
Voltage: AC220V.
Output type: transistor.
Outline dimension: 75*75*90.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment FR-F840-00250-2-60 Motor: HA-SH type.
Power: 1.0kw.
Speed: 3000r/min.
The speed regulating motor can be divided into a constant speed motor, a stepless constant speed motor, a stepless speed changing motor and a stepless speed changing motor,
Can also be divided into electromagnetic induction motor, DC motor, PWM variable frequency motor and switched reluctance motor.
The rotor speed of the induction motor is always slightly lower than that of the rotating magnetic field.
The rotor speed of the synchronous motor is not independent of the load size, but is always maintained as a synchronous speed. 8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc..
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddenly change.
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value).
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
FR-F840-00250-2-60 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FR-F840-00250-2-60&select=5