Motor series: medium inertia, medium power.
Rated output power: 3.5kw.
Rated speed: 3000r/min.
Whether to take the brake: No.
Shaft end: Standard (straight).
Protection level: IP65 (IP67).
Features: medium inertia from low speed to high speed three modes for selection, suitable for different applications.
Application examples: transmission machinery, robots, X-Y working platform.
High resolution encoder 131072p/rev (17 bit)
FR-A820-45K-1
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring. Applicable model: A956WGOT.Servo motor series: low inertia, low power.
Rated output: 0.75kw.
Rated speed: 3000r/min.
Electromagnetic brake: with.
Shaft end specification: Standard (straight axis).
Features: low inertia is widely used in general machinery.
IP level: IP65.
Application example:
1, belt drive.
2, industrial robots.
3, assembly machinery.
4, industrial sewing machine.
5, X-Y working table.
6, food processing machinery.
7, semiconductor manufacturing equipment.
8, knitting machine and embroidery machine.
Rotary servo motor.
Numerous motor series and wide motor power range can be used to meet different applications.
The protection level of the HF-KP/HF-MP/HC-LP/HC-RP/HC-UP servo motor to improve the environmental safety is IP65 (except the shaft part). Temperature sensor: PT100, 4 wire system.
The A1S62RD3 and A1S62RD4 temperature sensor input modules allow the platinum resistance temperature sensing element to be directly connected to the PLC,
This component converts a signal from a temperature measuring element to a numeric value that represents a temperature measurement value,
This temperature value can be used for the control process.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect.
FR-A820-45K-1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FR-A820-45K-1&select=5