LK Automation Limited LK Automation Limited
Information sort MITSUBISHI
Home >> Supply
FX3U-16CCL-M CC-Link connection module MITSUBISHI FX3U-16CCL-M Can be connected to FX3GA, FX3GE, FX3GC, FX3U and FX3UC of the host

Power: 7.5kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor FX3U-16CCL-M. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose FX3U-16CCL-M.) MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 5.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible FX3U-16CCL-M.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used MITSUBISHI FX3U-16CCL-M. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft MITSUBISHI FX3U-16CCL-M.
Station type: Master station.
Maximum number of stations: maximum 16.
Occupied points: 8 points.
Transfer speed: 10Mbps.
Power supply: 240mA DC24V.
Weight: 0.3kg.
FX3U-16CCL-M is the master module of V2 CC-LINK MITSUBISHI FX3U-16CCL-M.
The main station can be connected to 8 remote I/O stations, and 8 remote equipment station or intelligent equipment station.
Can be connected to FX3GA, FX3GE, FX3GC, FX3U and FX3UC of the host.
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V. Input and output points: 24 points.
Power supply: DC24V.
Input points: 14 points.
Output points: 10 points.
Output form: transistor output (source).
Power consumption: 21W.
Weight: 0.55KG.
Outline dimension: 90x90x86mm.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features.
Applicable to a wide variety of applications.
Basic unit: 24/40 point.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
A versatile PLC.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase.
High speed operation FX3U-16CCL-M.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function.