Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Input points: 24 points.
Output points: 16 points.
Power supply voltage: AC160-240V.
Output type: transistor output (drain) FX3U-64MT/ES-A datasheet PDF catalog FX3U-64MT/ES-A PDF datasheet.
A free combination of PLC
FX3U-64MT/ES-A
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points FX3U-64MT/ES-A datasheet PDF catalog FX3U-64MT/ES-A PDF datasheet.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. Needle number: 40.
Specification: loose wire connector, 5 sets (0.3mm 2). Function: bus conversion FX5 (connector) - FX3 FX3U-64MT/ES-A datasheet PDF catalog FX3U-64MT/ES-A PDF datasheet.
Input and output points: 8 points.
Conversion module connecting FX3 series expansion module.
FX3 series expansion module, only the right side of the bus conversion module can be connected. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 2.2KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
Speed control method of fan and pump equipment traditional by regulating the entrancee or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs of closure FX3U-64MT/ES-A datasheet PDF catalog FX3U-64MT/ES-A PDF datasheet FX3U-64MT/ES-A datasheet PDF catalog FX3U-64MT/ES-A PDF datasheet.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.