LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Catalog Download
MITSUBISHI AJ65SBTB1B-16TE1 datasheet PDF catalog AJ65SBTB1B-16TE1 PDF datasheet
Product model: AJ65SBTB1B-16TE1
Name: Transistor output module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0 AJ65SBTB1B-16TE1 datasheet PDF catalog AJ65SBTB1B-16TE1 PDF datasheet. 1A AJ65SBTB1B-16TE1
External connection: 3 line /2 line type.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. D-STN color / monochrome LCD man-machine interface to replace the backlight.
Applicable model: A970GOT-SB_/LB_ AJ65SBTB1B-16TE1 datasheet PDF catalog AJ65SBTB1B-16TE1 PDF datasheet. Adapter for mounting rails. Unit connection CPU unit.Cable length 1m; used in A6TE2-16SRN.A1SCPUC24-R2 integrates all functions of A1SCPU with a dedicated RS232 interface,
It maintains the compatibility of CPU ANS and is easy to use.
The built-in RS232 interface makes it can connect bar code reader, operator interface, computer and so on,
Realization of low cost data communication.
A1SCPUC24-R2 is a combination of A1SCPU and A1SJ71C24-R2 features of the two components together AJ65SBTB1B-16TE1 datasheet PDF catalog AJ65SBTB1B-16TE1 PDF datasheet.
It maintains the compatibility and communication specifications for the two component programming.
Fixed this A1SCPU and A1SJ71C24-R2 programming method applied to A1SCPUC24-R2. Multi axis positioning controller.
Program capacity: Max 60K step.
Input / output points: 1920 points.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. Multi axis positioning controller.
Optical data communication line.
Program capacity: Max 60K step.
Input / output points: 1920 points.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler.
User program storage capacity: it is a measure of how much the user application can store thee number of indicators AJ65SBTB1B-16TE1 datasheet PDF catalog AJ65SBTB1B-16TE1 PDF datasheet.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words AJ65SBTB1B-16TE1 datasheet PDF catalog AJ65SBTB1B-16TE1 PDF datasheet. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Input module
AJ65SBTB3-16KD
MITSUBISHI Input module AJ65SBTB3-16KD
Input type: DC input, positive pulic en
MITSUBISHI
Input module
AJ65SBTB1-32D
MITSUBISHI Input module AJ65SBTB1-32D
Input type: DC input, positive pulic en
MITSUBISHI
Relay output module
AJ65SBTB2N-16R
MITSUBISHI Relay output module AJ65SBTB2N-16R
Output type: relay output. Output points
MITSUBISHI
Transistor output module
AJ65SBTB1-16T
MITSUBISHI Transistor output module AJ65SBTB1-16T
Output type: transistor output, drain ty