LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Catalog Download
MITSUBISHI AJ65SBTB32-16KDT2 datasheet PDF catalog AJ65SBTB32-16KDT2 PDF datasheet
Product model: AJ65SBTB32-16KDT2
Name: DC input / transistor output module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
3C-2V/5C-2V coaxial cable between the single bus PC network (control station / common station) / remote I/O network (remote master).
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on AJ65SBTB32-16KDT2 datasheet PDF catalog AJ65SBTB32-16KDT2 PDF datasheet AJ65SBTB32-16KDT2
This phenomenon is called the I/O delay time effect.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order AJ65SBTB32-16KDT2 datasheet PDF catalog AJ65SBTB32-16KDT2 PDF datasheet.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Cable length: 30 meters AJ65SBTB32-16KDT2 datasheet PDF catalog AJ65SBTB32-16KDT2 PDF datasheet.
For connection between GOT and CRT. DC input points: 16 points.
Input voltage and current: 3/7mA, DC12/24V.
Response time: 10ms.
Positive pole sharing.
16 point /1 a public side.
Output points: 12 points.
Output voltage and current: DC12/24V, 0.5A/1 point, 3.2A/1 common end.
Response time: 2ms.
8 point /1 a public end, 4 point /1 a public end.
Output form: transistor output, leakage type.
36 point terminal station.
Number of stations: 4 stops.
Compact remote I/O unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness AJ65SBTB32-16KDT2 datasheet PDF catalog AJ65SBTB32-16KDT2 PDF datasheet AJ65SBTB32-16KDT2 datasheet PDF catalog AJ65SBTB32-16KDT2 PDF datasheet.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
Input module
AJ65SBTB1-32D1
MITSUBISHI Input module AJ65SBTB1-32D1
Input type: DC input, positive pulic en
MITSUBISHI
Input module
AJ65SBTB3-16D5
MITSUBISHI Input module AJ65SBTB3-16D5
Input type: DC input, positive pulic en