MITSUBISHI AD75M1 datasheet PDF catalog AD75M1 PDF datasheet
Product model: AD75M1
Name: Positioning module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Available network: Profibus-FMS.
Function: client or host.
The A1SJ71PB96F and A1SJ71PB92D modules allow a PLC ANS to connect to the Profibus system,
Meet the CE standard, using SWOIX/ProfiMap special programming software.
A1SJ71PB96F compatible with Profibus-FMS, as a master or client;
A1SJ71PB92D compatible with Profibus-DP, can be used as a master to control the remote Profibus-DP I/O AD75M1 datasheet PDF catalog AD75M1 PDF datasheet AD75M1 AnS, QnAS bus connection, the reader to write program 1 channel connection.Output points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
38 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor AD75M1 datasheet PDF catalog AD75M1 PDF datasheet.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc AD75M1 datasheet PDF catalog AD75M1 PDF datasheet. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valvee with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AD75M1 datasheet PDF catalog AD75M1 PDF datasheet AD75M1 datasheet PDF catalog AD75M1 PDF datasheet.
Related products
MITSUBISHI
Positioning module
AD75P1-S3
MITSUBISHI Positioning module AD75P1-S3
1 axes. 2 axis linear interpolation, 2 a
MITSUBISHI
Positioning module
AD75M1
MITSUBISHI Positioning module AD75M1
1 axes. Control unit: pulse, mm, inch, d
MITSUBISHI
Positioning module
AD71-S7
MITSUBISHI Positioning module AD71-S7
2 axes. 2 axis linear interpolation. Con