MITSUBISHI QX48Y57 Manual QX48Y57 User's Manual
Product model: QX48Y57
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: N type (positive public end / negative public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features QX48Y57 Manual QX48Y57 User's Manual QX48Y57
Saving wiring by CC-link connection.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces.
Visualization of installation status.
Can monitor the safe output, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start QX48Y57 Manual QX48Y57 User's Manual. 8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc..
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored QX48Y57 Manual QX48Y57 User's Manual.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddenly change.
By detectting the transient peak current at this time, the fault of the equipment can be diagnosed QX48Y57 Manual QX48Y57 User's Manual.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) QX48Y57 Manual QX48Y57 User's Manual.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
Related products
MITSUBISHI
Type DC input module
QX41-S1
MITSUBISHI Type DC input module QX41-S1
Input points: 32 points. Input voltage a
MITSUBISHI
Type DC input module
QX42-S1
MITSUBISHI Type DC input module QX42-S1
Input points: 64 points. Input voltage a
MITSUBISHI
Type DC input module
QX41
MITSUBISHI Type DC input module QX41
Input points: 32 points. Input voltage a
MITSUBISHI
Type DC input module
QX42
MITSUBISHI Type DC input module QX42
Input points: 64 points. Input voltage a