Battery replacement.
Initial voltage 3.0V.
Current capacity: 5000mAh.
Service life: 5 years.Control axis: up to 32 axes.
Servo amplifier connection mode: SSCNET III /H (2 system).
Can be carried out with a high degree of control, free correspondence.
Large scale and medium scale system.
Maximum number of control axis: 32 axis (Q173DSCPU), 16 axis (Q172DSCPU) QX40 datasheet PDF catalog QX40 PDF datasheet
QX40
Programmable controller CPU and C language controller can be selected according to the purpose.
By using 3 sets of Q173DSCPU, 96 axes can be controlled.
Support security monitoring function, visual system.SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Controller network (control station / common station) / remote I/O network (remote master station) QX40 datasheet PDF catalog QX40 PDF datasheet.
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference QX40 datasheet PDF catalog QX40 PDF datasheet.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Three-phase 3 wire type.
Measuring circuit number: 4 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products QX40 datasheet PDF catalog QX40 PDF datasheet.
For example, a module ccan be used to measure other loads from the control panel trunk QX40 datasheet PDF catalog QX40 PDF datasheet.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.