MITSUBISHI Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Manual
Product model: Q50UDEHCPU
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Manual
File language: English
1 slots; no power supply; used to install large PLC series AnS module.
Base plate of AnS series PLC.
QA1S series PLC 1 slot main substrate.
AnS series of modules can be installed. Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0 Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Manual. 2.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program Q50UDEHCPU
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Manual. The telephone line of the interface module is connected with the peripheral equipment.8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Manual.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc..
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddenly change.
By detecting the transient peak currrent at this time, the fault of the equipment can be diagnosed Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Manual.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Manual.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
Related products
MITSUBISHI
With Ethernet CPU
Q50UDEHCPU
MITSUBISHI With Ethernet CPU Q50UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q13UDEHCPU
MITSUBISHI With Ethernet CPU Q13UDEHCPU
Input / output points: 4096 points. Num