Upgraded version.
Control axis: maximum 8 axes.
Peripheral I/F: by CPU PLC.
Manual pulse generator operation function: can use 3 sets of manual pulse generator.
Synchronous encoder operation function: can use 8 synchronous encoder.
CPU special high speed communication bus, each 0.88ms cycle can exchange 14K data word Q10UDEHCPU Application Functions Manual Q10UDEHCPU Programming Manual.
Exercise basic performance is about 2 times, sports SFC processing time is reduced by about 1/4
Q10UDEHCPU
PLC interrupt program to achieve high-speed synchronization between multiple CPU.
Motion specific instructionInput points: 8 points.
Input voltage and current: AC100 ~ 240V; 17mA (AC200V; 60Hz) /14mA (AC200V; 50Hz) /8mA (AC100V; 60Hz) /7mA (AC100V; 50Hz); () ().
Response time: 20ms Q10UDEHCPU Application Functions Manual Q10UDEHCPU Programming Manual.
8 points / a common end.
18 point terminal station.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields Q10UDEHCPU Application Functions Manual Q10UDEHCPU Programming Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q10UDEHCPU Application Functions Manual Q10UDEHCPU Programming Manual. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q10UDEHCPU Application Functions Manual Q10UDEHCPU Programming Manual.