MITSUBISHI Q4ACPU SFC Manual Q4ACPU PROGRAMMING MANUAL
Product model: Q4ACPU
Name: Programmable Controller
Brand: MITSUBISHI
Sort: SFC PROGRAMMING MANUAL
File language: English
4 axis, differential drive output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 4Mpps.
40 pin connector.
Differential output.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing Q4ACPU SFC Manual Q4ACPU PROGRAMMING MANUAL Q4ACPU
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q4ACPU SFC Manual Q4ACPU PROGRAMMING MANUAL.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q4ACPU SFC Manual Q4ACPU PROGRAMMING MANUAL.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown. Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 2A.
Ultra thin power supply.
Simplified program debugging
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long hooliday and other planned downtime,
The data is lost due to battery depletion Q4ACPU SFC Manual Q4ACPU PROGRAMMING MANUAL.
The next time the power is turned on, the backup data will be automatically restored.
Through the expansion of soft components,, more convenient to create the program Q4ACPU SFC Manual Q4ACPU PROGRAMMING MANUAL.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Related products
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
General purpose CPU
Q00UCPU
MITSUBISHI General purpose CPU Q00UCPU
nput / output points: 1024 points. Nume
MITSUBISHI
Secure CPU module
QS001CPU
MITSUBISHI Secure CPU module QS001CPU
Control mode: loop program execution. In