Battery replacement.
Initial voltage 3.0V.
Base of large capacity battery.
Current capacity: 5000mAh.
Service life: 5 years.Input / output points: 256 points.
Program capacity: 8 K step.
Processing speed: 0.2 s.
Built in communication port: RS232*1.
Continue to go beyond, to climb the peak of Q series Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Guide.
Strengthen security function.
Can be set up to 32 characters of the file password Q50UDEHCPU
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Guide.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA.
Conversion speed (output):25ms/2 channel Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Guide.
18 point terminal station.
With 5 kinds of PID control mode.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc..
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response.
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analog.
Proovides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integratiion time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Guide Q50UDEHCPU Structured Text Manual Q50UDEHCPU Programming Guide.
Related products
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q20UDEHCPU
MITSUBISHI With Ethernet CPU Q20UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q100UDEHCPU
MITSUBISHI With Ethernet CPU Q100UDEHCPU
Input / output points: 4096 points. Num