MITSUBISHI Q25PHCPU MELSAP-L Manual Q25PHCPU Programming Manual
Product model: Q25PHCPU
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
Control axis: maximum 8 axes.
Peripheral I/F: by CPU PLC.
Manual pulse generator operation function: can use 3 sets of manual pulse generator.
Synchronous encoder operation function: can use 8 synchronous encoder.
CPU special high speed communication bus, each 0.88ms cycle can exchange 14K data word Q25PHCPU MELSAP-L Manual Q25PHCPU Programming Manual.
Exercise basic performance is about 2 times, sports SFC processing time is reduced by about 1/4 Q25PHCPU
PLC interrupt program to achieve high-speed synchronization between multiple CPU.
Motion specific instruction.Battery replacement.
Initial voltage 3.0V.
Replacement of large capacity battery module without cable.
Current capacity: 18000mAh.
Service life: 5 years.
Outline dimension: 98*55.2*87mm.5 slots Q25PHCPU MELSAP-L Manual Q25PHCPU Programming Manual.
No need for power.
Used to install large Q series modules.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q25PHCPU MELSAP-L Manual Q25PHCPU Programming Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Wider application range, more advanced.
Leading in the era of the Q series CPU products.
Q series CPU products a wide range of applications,
Provide programmable controller, process, redundancy, C language, movement, manipulator, CNC all kinds of CPU,
In order to meet the needs of various control.
Through the multi CPU configuration, can be based on the use of the scale, purpose,
Construction of the best system to meet the requirements of all kinds of control.
In addition, the high reliability system can be constructed by the redundant system,
Even if a fault occurs, the systtem can continue to run Q25PHCPU MELSAP-L Manual Q25PHCPU Programming Manual. Extended SRAM card 8MB
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the changge of the specified control data without any omission Q25PHCPU MELSAP-L Manual Q25PHCPU Programming Manual.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis.
Related products
MITSUBISHI
Motion CPU module
Q172HCPU
MITSUBISHI Motion CPU module Q172HCPU
Control axis: maximum 8 axes. Teaching o
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q10UDEHCPU
MITSUBISHI With Ethernet CPU Q10UDEHCPU
Input / output points: 4096 points. Num