Battery replacement.
Initial voltage 3.0V.
Replace large capacity battery module with cable.
Current capacity: 18000mAh.
Service life: 5 years.
Outline dimension: 98*55.2*87mmInput: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel Q25HCPU Common Instructions Manual Q25HCPU Programming Manual.
Output: DC4~20mA
Q25HCPU
Conversion speed (output):25ms/2 channel.
18 point terminal station.
With 5 kinds of PID control mode.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc..
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output Q25HCPU Common Instructions Manual Q25HCPU Programming Manual.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response.
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analog Q25HCPU Common Instructions Manual Q25HCPU Programming Manual.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integration time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station. Three-phase 3 wire type.
Measuring circuit number: 4 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phasse 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q25HCPU Common Instructions Manual Q25HCPU Programming Manual.
For example, a module ccan be used to measure other loads from the control panel trunk Q25HCPU Common Instructions Manual Q25HCPU Programming Manual.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.