MITSUBISHI Q13UDVCPU MELSAP-L Manual Q13UDVCPU Programming Manual
Product model: Q13UDVCPU
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
8 slots.
Extended substrate.
Double power supply mode power supply redundancy system.
Used to install Q series modules.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc Q13UDVCPU MELSAP-L Manual Q13UDVCPU Programming Manual. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q13UDVCPU
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Wider application range, more advanced.
Leading in the era of the Q series CPU products Q13UDVCPU MELSAP-L Manual Q13UDVCPU Programming Manual.
Q series CPU products a wide range of applications,
Provide programmable controller, process, redundancy, C language, movement, manipulator, CNC all kinds of CPU,
In order to meet the needs of various control.
Through the multi CPU configuration, can be based on the use of the scale, purpose,
Construction of the best system to meet the requirements of all kinds of control.
In addition, the high reliability system can be constructed by the redundant system,
Even if a fault occurs, the system can continue to run Q13UDVCPU MELSAP-L Manual Q13UDVCPU Programming Manual. Cable length 0.6 meters.
Extended substrate for connection.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q13UDVCPU MELSAP-L Manual Q13UDVCPU Programming Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q13UDVCPU MELSAP-L Manual Q13UDVCPU Programming Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products
MITSUBISHI
With Ethernet CPU
Q13UDEHCPU
MITSUBISHI With Ethernet CPU Q13UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
General high speed CPU
Q13UDVCPU
MITSUBISHI General high speed CPU Q13UDVCPU
Input / output points: 4096 points. Inpu
MITSUBISHI
General high speed CPU
Q06UDVCPU
MITSUBISHI General high speed CPU Q06UDVCPU
Input / output points: 4096 points. Inpu
MITSUBISHI
General purpose CPU
Q13UDHCPU
MITSUBISHI General purpose CPU Q13UDHCPU
Input / output points: 4096 points. Num