LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI Q06UDEHCPU Structured Text Manual Q06UDEHCPU Programming Guide Book
Product model: Q06UDEHCPU
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Guide Book
File language: English
Control axis: maximum 32 axes.
Teaching running function: there (when using SV13).
Compact size and space saving.
Using the same hardware structure and MELSEC-Q series PLC, to achieve the same product installation area, the size of the industry.
Using 12 slot substrate, more space and cost savings.
Can share PLC MELSEC-Q power module, substrate, and I/O module Q06UDEHCPU Structured Text Manual Q06UDEHCPU Programming Guide Book Q06UDEHCPU
The control process can be assigned to each CPU module in the multi CPU system, which is equivalent to the intelligent control system.
In PC (Computer Personal) CPU.Master / local station sharing.
IE CC-Link field network.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module Q06UDEHCPU Structured Text Manual Q06UDEHCPU Programming Guide Book.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller Q06UDEHCPU Structured Text Manual Q06UDEHCPU Programming Guide Book.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
QJ71GF11-T2 can be used as the main station / local station of IE CC-Link field network.Control axis: maximum 32 axes.
Teaching running function: there (when using SV13).
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After starting the specified location to stop the instruction,
CCan be set in advance to stop the location Q06UDEHCPU Structured Text Manual Q06UDEHCPU Programming Guide Book.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / decelleration time Q06UDEHCPU Structured Text Manual Q06UDEHCPU Programming Guide Book.
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.
Related products
MITSUBISHI
General purpose CPU
Q06UDHCPU
MITSUBISHI General purpose CPU Q06UDHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q20UDEHCPU
MITSUBISHI With Ethernet CPU Q20UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
General high speed CPU
Q06UDVCPU
MITSUBISHI General high speed CPU Q06UDVCPU
Input / output points: 4096 points. Inpu