Output points: 16 points.
Output voltage and current: 12~24V 0.1A/; DC point; 1.6A/ common.
OFF leakage current: 0.1mA;
Response time: 1ms; 1 point 16 public end; leaky type.
18 point terminal station
With heat protection.
With short circuit protection.
With the surge absorber.
Continue to go beyond, to climb the peak of Q series Q06PHCPU Common Instructions Manual Q06PHCPU Programming Manual.
Strengthen security function
Q06PHCPU
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights Q06PHCPU Common Instructions Manual Q06PHCPU Programming Manual.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields Q06PHCPU Common Instructions Manual Q06PHCPU Programming Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.Input and output points: 1024 points.
Input / output data points: 8192 points.
Program capacity: 60k.
Basic command processing speed (LD command) S:0.075.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The conttents of the output status register are changed with the execution of the program Q06PHCPU Common Instructions Manual Q06PHCPU Programming Manual.
Output refresh phase: when all instructions are executed,
The output status register is sent to the ooutput latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment Q06PHCPU Common Instructions Manual Q06PHCPU Programming Manual.