MITSUBISHI LY10R2 Manual LY10R2 User's Manual
Product model: LY10R2
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Number of input channels: 4ch.
Input voltage: DC - 10 - 10V.
Input current: DC0 ~ 20mA.
Input voltage: 100 ~ 100mV / minute.
Input thermocouple: K, J, T, E, N, R, S, B, U, L, PL II, W5Re/W26Re.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50.
Conversion speed: 50ms/ch.
Resolution (voltage / current / micro voltage): 1/20000
Resolution (thermocouple): B, R, S, N, PL II, W5Re/W26Re:0 LY10R2 Manual LY10R2 User's Manual LY10R2 3,, K, E, J, T, U, L:0.1.
Temperature measuring resistance: Pt100, JPt100:0.03, /0.1, Pt1000, Pt50:0.1.
Reduce the programming time.
The digital output value can be easily converted (zoom) to any number of functions without the program.
No need to use ladder diagram conversion program, can reduce the programming time LY10R2 Manual LY10R2 User's Manual.
Zoom setting example (L60AD4-CM).
The digital output value (20000 ~ 0) of the input range 20mA ~ 4mA is scaled to the value of positive and negative 20000.
Digital filter function
Simply set the parameters, you can eliminate the function of the redundant frequency components.
Can be selected from low pass filter, high pass filter, medium pass filter.
No need to filter the ladder, can reduce programming time LY10R2 Manual LY10R2 User's Manual.
In addition, the conversion value of the A/D converted by the filter can be obtained at the same time,
Therefore, the total processing time from the conversion to the filter processing can be shortened. "Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 40ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
HHigh precision PWM control of the highest 200kHz LY10R2 Manual LY10R2 User's Manual.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming coontrol, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators LY10R2 Manual LY10R2 User's Manual. "
Related products
MITSUBISHI
RS-232 cable
GT09-C30R2-9P
MITSUBISHI RS-232 cable GT09-C30R2-9P
Cale length: 3m. Connection etween ser
MITSUBISHI
RS-232C cable
AC30R2-9SS
MITSUBISHI RS-232C cable AC30R2-9SS
Cale length: 3 meters. Connection etwe
MITSUBISHI
Programming cable
QC30R2
MITSUBISHI Programming cable QC30R2
RS232 cale for connecting cales and 3M
MITSUBISHI
RS-232 cable
GT01-C30R2-25P
MITSUBISHI RS-232 cable GT01-C30R2-25P
Cale length: 3m. Adapter for use in the