MITSUBISHI LX42C4 Manual LX42C4 User's Manual
Product model: LX42C4
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Temperature measurement resistor input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode LX42C4 Manual LX42C4 User's Manual.
Temperature regulation mode.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function LX42C4
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
Can make multi loop to reach the target value (SV) of the same time LX42C4 Manual LX42C4 User's Manual.
By setting the simultaneous heating of the channel group, up to 2 groups of units, respectively, at the same time warming.
It is very effective to use the control object that does not want to heat up to the time of arrival error.
Applicable to a variety of systems.
Sampling period switching function.
Sampling period can be selected from 250ms/4ch and 500ms/4ch LX42C4 Manual LX42C4 User's Manual.
Equipped with temperature input mode.
The temperature control module can be used as a temperature input module.
By setting the switch, you can easily change the input mode. Differential output.
Axis of control: 2.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can bbe displayed in real time LX42C4 Manual LX42C4 User's Manual.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display LX42C4 Manual LX42C4 User's Manual.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.
Related products
MITSUBISHI
DC input module
LX40C6-CM
MITSUBISHI DC input module LX40C6-CM
Input points: 16 points. Rated input vol
MITSUBISHI
Input module
RX42C4
MITSUBISHI Input module RX42C4
"Enter points: 64 points. Rated input vo
MITSUBISHI
DC input module
LX42C4-CM
MITSUBISHI DC input module LX42C4-CM
Enter points: 64 points. Rated input vol
MITSUBISHI
Input / output mixed module
LH42C4NT1P-CM
MITSUBISHI Input / output mixed module LH42C4NT1P-CM
Input points: 32 points. Input voltage: