Output points: 8 points.
Output form: no public side (all points independent).
Rated output voltage: AC100 ~ 240V.
Max load current: 1A/1 point.
Common way: no public side (all points of independence).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal L26CPU-PBT Structured Text Manual L26CPU-PBT Programming Manual.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system
L26CPU-PBT
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged L26CPU-PBT Structured Text Manual L26CPU-PBT Programming Manual.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability L26CPU-PBT Structured Text Manual L26CPU-PBT Programming Manual. Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (drain).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points).
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolattion L26CPU-PBT Structured Text Manual L26CPU-PBT Programming Manual.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible L26CPU-PBT Structured Text Manual L26CPU-PBT Programming Manual.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.