Differential output.
Axis of control: 2.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start L26CPU-PBT Application Manual L26CPU-PBT User's Manual
L26CPU-PBT
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check L26CPU-PBT Application Manual L26CPU-PBT User's Manual.
Can only choose the necessary items from the rich monitoring information and monitor the display.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action. Input points: 16 points.
Rated input voltage: DC24V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points) L26CPU-PBT Application Manual L26CPU-PBT User's Manual.
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on. CC-Link/LT master station.
Transmission speed: 2.5Mbps.
Remote input / output: 1024 points.
16 point mode.
In the cabinet, the device can also respond to high speed.
CC-Link/LT link scan time to reach the highest 1.2ms (2.5Mbps) at 664 stations,
Excellent response performance is achieved L26CPU-PBT Application Manual L26CPU-PBT User's Manual.
Can be selected according to the transmission distance 2.5Mbps, 625kbps, 156kbps.
Comfortable environment without network awareness.
Paraameter settings that do not require any trouble L26CPU-PBT Application Manual L26CPU-PBT User's Manual.
Moreover, the transmission speed only through the master module to set, can easily use the remote I/O.