MITSUBISHI L26CPU-BT Function Explanation, Program Fundamentals Manual L26CPU-BT User's Manual
Product model: L26CPU-BT
Name: CPU Module
Brand: MITSUBISHI
Sort: Function Explanation, Program Fundamentals User's Manual
File language: English
Maximum transmission speed: 115.2kbps.
DC5V internal consumption current: 0.15A.
Weight: 0.12kg.
GOT connection.
MELSOFT connection.
Communication protocol support function serial communication function. Input and output (DC/ differential).
Input points: 12 points (DC5V/DC24V/ differential universal) Program Fundamentals Manual L26CPU-BT User's Manual.
Pulse input speed: the highest pulse/s 8M (2MHz) L26CPU-BT
Output points: 8 points (DC5V ~ DC24V) 6 points (differential).
Pulse output speed: the highest pulse/s 8M (2MHz).
High speed and stable input / output response
The high speed response can be achieved without the CPU module''s operation and bus performance,
Stable input and output response through hardware processing.
LD40PD01 is equipped with an external input and output interface and FPGA,
Therefore, high speed control can be realized without the influence of the scanning time of the CPU module and the bus performance (the input and output response time of the s instruction is realized) Program Fundamentals Manual L26CPU-BT User's Manual.
Can achieve stable input and output response (processing time of the deviation of the ns level).
Through the intuitive tools for FPGA settings.
In the FPGA design process can be omitted in the past must be designed to deal with (HDL description, logic synthesis and time verification),
Reduce working hours Program Fundamentals Manual L26CPU-BT User's Manual. After receiving the product can be used immediately to verify the use of special tools, can significantly shorten the design time. Temperature measurement resistor input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
Can make multi loop to reach the target value (SV) of the same time.
By setting the simultaneous heating of the channel group, up to 2 groups of units, respectively, at the same time warming.
It is very effective to use the control objectt that does not want to heat up to the time of arrival error L26CPU-BT Function Explanation.
Applicable to a variety of systems.
Sampling period switching function.
Sampling period can be selected from 250ms/4ch and 500ms/4ch.
Equipped with temperatture input mode L26CPU-BT Function Explanation.
The temperature control module can be used as a temperature input module.
By setting the switch, you can easily change the input mode.
Related products
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L26CPU-BT-CM
MITSUBISHI cpu module L26CPU-BT-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type.