LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI L06CPU-CM Structured Text Manual L06CPU-CM Programming Manual
Product model: L06CPU-CM
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Manual
File language: English
RS-232, RS-422/485.
Transmission speed: 230.4kbps.
MC protocol.
Communication protocol support function.
Can only be used on the ch1 side.
Device for immediate communication
Communication protocol support function through Works2 GX,
Can easily set the required agreement with the other equipment communication L06CPU-CM Structured Text Manual L06CPU-CM Programming Manual.
In addition, only the communication protocol library is required to select the equipment to be carried out,
Immediate connection L06CPU-CM
The creation and editing of communication protocols are simple and easy to implement, even if there is no connection equipment in the communication protocol library,
Can also simply create a corresponding protocol for communication.
The content of the communication protocol that can be created in the list,
Can also be simply edited L06CPU-CM Structured Text Manual L06CPU-CM Programming Manual. Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (source).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points) L06CPU-CM Structured Text Manual L06CPU-CM Programming Manual.
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isollation L06CPU-CM Structured Text Manual L06CPU-CM Programming Manual.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible L06CPU-CM Structured Text Manual L06CPU-CM Programming Manual.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.
Related products
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L02CPU-CM
MITSUBISHI cpu module L02CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type