MITSUBISHI L02SCPU-CM Common Instructions Manual L02SCPU-CM Programming Manual
Product model: L02SCPU-CM
Name: PLC
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
"IE Field CC-Link master / local station
Transmission speed: 1Gbps.
Remote input / output: 16384 points.
Remote register: 8192 words.
Can be applied to the serial number of the top 5 for the "13012" and after the CPU module.
Simply set the parameters, you can easily start the network.
Simply use the Works2 GX, set the network parameters in the 1 master station, you can easily connect all the slave stations L02SCPU-CM Common Instructions Manual L02SCPU-CM Programming Manual L02SCPU-CM
Also, when you need to change the system, you only need to change the parameters.
High degree of freedom network
Build star, linear, star and linear mixed model, and ring network,
Therefore, can freely set the scene equipment.
When you use HUB, you just need to connect the cable to the free port to build the network easily,
Additional equipment and re layout of the corresponding is also more simple L02SCPU-CM Common Instructions Manual L02SCPU-CM Programming Manual. "Thermocouple input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode L02SCPU-CM Common Instructions Manual L02SCPU-CM Programming Manual.
Temperature regulation mode.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperaturre control of the extrusion molding machine can prevent over heating and cooling L02SCPU-CM Common Instructions Manual L02SCPU-CM Programming Manual.
According to the object device can choose any one of the following control method.
Standard controol (heating or cooling) L02SCPU-CM Common Instructions Manual L02SCPU-CM Programming Manual.
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).
Related products
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L02CPU-CM
MITSUBISHI cpu module L02CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type