Output points: 8 points (independent of all points).
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Public side mode: no public side (all points of independent contact).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal L02CPU-CM Application Manual L02CPU-CM User's Manual.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called
L02CPU-CM
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch L02CPU-CM Application Manual L02CPU-CM User's Manual.
Communication protocol is a standard Modbus protocol or custom protocol. DC input.
Number of input channels: 2Ch.
DC5/12/24V input.
Maximum count rate: pulse/s 200k.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control L02CPU-CM Application Manual L02CPU-CM User's Manual.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized. RS-232, RS-422/485.
Transmission speed: 230.4kbps.
MC protocol.
Communication protocol support function.
Can only be used on the ch1 side.
Device for immediate communication
Communication protocol support function through Works2 GX,
Can easily set the required agreement with the other equipment communication.
In addition, only the communication protocol library is required to select the equipment to be carried out,
Immediate cconnection L02CPU-CM Application Manual L02CPU-CM User's Manual.
The creation and editing of communication protocols are simple and easy to implement, even if there is no connection equipment in the communication protocol library,
Can also simply crreate a corresponding protocol for communication L02CPU-CM Application Manual L02CPU-CM User's Manual.
The content of the communication protocol that can be created in the list,
Can also be simply edited.