LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI FX2N-48MR-ES/UL Manual FX2N-48MR-ES/UL PROGRAMMING MANUAL II
Product model: FX2N-48MR-ES/UL
Name: PLC
Brand: MITSUBISHI
Sort: PROGRAMMING MANUAL II
File language: English
Max input / output points: 48 points.
Power supply voltage: 24VDC.
Input points: 24 points.
Output points: 24 points.
Output type: relay.
Power consumption: 30W.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation FX2N-48MR-ES/UL Manual FX2N-48MR-ES/UL PROGRAMMING MANUAL II FX2N-48MR-ES/UL
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FX2N-48MR-ES/UL Manual FX2N-48MR-ES/UL PROGRAMMING MANUAL II.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). RS-485 communication. Special communication adapter.Output points: 16 points.
Relay output type. MITSUBISHI inverter FR-F720 series FX2N-48MR-ES/UL Manual FX2N-48MR-ES/UL PROGRAMMING MANUAL II.
Voltage level: three phase 200V.
Frequency converter capacity: 1.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 22kw.
SLD converter rated current: 125A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of the pump machine, in addition to thee pump for power frequency drive FX2N-48MR-ES/UL Manual FX2N-48MR-ES/UL PROGRAMMING MANUAL II.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted too a more intuitive display unit% units FX2N-48MR-ES/UL Manual FX2N-48MR-ES/UL PROGRAMMING MANUAL II.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display.
Related products
MITSUBISHI
PLC
FX2N-48MR-DS
MITSUBISHI PLC FX2N-48MR-DS
Max input / output points: 48 points. Po
MITSUBISHI
Input / output module
FX2N-8ER-ES/UL
MITSUBISHI Input / output module FX2N-8ER-ES/UL
Input and output form: DC input, relay o
MITSUBISHI
PLC
FX1S-20MR-ES/UL
MITSUBISHI PLC FX1S-20MR-ES/UL
Max input / output points: 20 points. Su